shengyi technology co., ltd.-8858cc永利官网

product

s3116

characteristic

● excellent tracking resistance,cti600v

● excellent thermal resistance, and moisture resistance, good mechanical properties and electrical properties.

application area

● power base board, display, ultrasonic machine, electric appliances used in high-temperature high-pressure, moist and dirty situation
  • product performance
  • product certificate
  • data download
items method condition unit typical value
cte (z-axis) ipc-tm-650 2.4.24 before tg ppm/℃
after tg ppm/℃
50-260℃ % 6.5
t260 ipc-tm-650 2.4.24.1 tma min 5
thermal stress ipc-tm-650 2.4.13.1 288℃, solder dip -- 30s no delamination
volume resistivity ipc-tm-650 2.5.17.1 after moisture resistance mω.cm 5.3 x 108
e-24/125 mω.cm 3.1 x 105
surface resistivity ipc-tm-650 2.5.17.1 after moisture resistance 7.1 x 107
e-24/125 6.3 x 106
arc resistance ipc-tm-650 2.5.1 d-48/50 d-4/23 s 120
dielectric breakdown ipc-tm-650 2.5.6 d-48/50 d-4/23 kv 45 kv nb
dissipation constant (dk) ipc-tm-650 2.5.5.9 1mhz -- 4.5
iec 61189-2-721 10ghz --
dissipation factor (df) ipc-tm-650 2.5.5.9 1mhz -- 0.021
iec 61189-2-721 10ghz --
peel strength(1oz hte copper foil) ipc-tm-650 2.4.8 a n/mm
after thermal stress 288℃,10s n/mm 1.8
125℃ n/mm 1.6
flexural strength lw ipc-tm-650 2.4.4 a mpa 400
cw ipc-tm-650 2.4.4 a mpa 350
water absorption ipc-tm-650 2.6.2.1 e-1/105 d-24/23 % 0.13
cti iec60112 a rating plc 0
flammability ul94 c-48/23/50 rating v-0
e-24/125 rating v-0

remarks:

1. specification sheet: ipc-4101/30 , is for your reference only.

2. all the typical value is based on the 1.6mm specimen.

3. all the typical values listed above are for your reference only and not intended for specification. please contact shengyi technology co., ltd. for detailed information. all rights from this data sheet are reserved by shengyi technology co., ltd.

explanation: c=humidity conditioning, d=immersion conditioning in distilled water, e=temperature conditioning

the first digit following the letter indicates the duration of preconditioning in hours, the second digit the preconditioning temperature in ℃ and the third digit the relative humidity.

网站地图